SENSORS
More information online at bannerengineering.com324
LIGHT GAUGING ULTRASONIC MEASURING ARRAYS RADAR
U-GAGE
®
T30U Specifications
Effective Beam
See Chart EPBC-7 to EPBC-11 on page 327.
Sensing Range
“A” suffix models: 150 mm min. near limit; 1 m max. far limit
“B” suffix models: 300 mm min. near limit; 2 m max. far limit
“-CRFV” models: 300 mm min. near limit; 1.5 m max. far limit
Supply Voltage and Current
Current sourcing analog output models: 12 to 24V dc (10% max. ripple); 90 mA (exclusive of load)
Voltage sourcing analog output models: 15 to 24V dc (10% max. ripple); 90 mA (exclusive of load)
Dual-discrete output models: 12 to 24V dc (10% max. ripple); 90 mA (exclusive of load)
Ultrasonic Frequency
Short Range: 228 kHz
Long Range: 128 kHz
Supply Protection Circuitry
Protected against reverse polarity and transient voltages.
Output Protection
Protected against continuous overload and short-circuit; transient over-voltage; no false pulse on power-up.
Output Configuration
Discrete (switched) output: Solid-state switch conducts when target is sensed within sensing window;
choose NPN (current sinking) or PNP (current sourcing) models.
Analog output: Choose 0 to 10V dc sourcing or 4 to 20 mA sourcing output models; output slope may be
selected using TEACH sequence.
Output Ratings
Discrete (switched) output: 100 mA max., total–both outputs
OFF-state leakage current: less than 10 µA
ON-state saturation voltage: less than 1V at 10 mA and less than 1.5V at 100 mA
Analog Output:
Voltage sourcing: 0 to 10V dc (at 1 kΩ min. resistance)
Current sourcing: 4 to 20 mA, 1 Ω to Rmax.
Rmax = V
supply
- 7V
20 mA
Output Response Time
Discrete output: “A” suffix models: 48 milliseconds
“B” suffix models: 96 milliseconds
Analog output: “A” suffix models: 48 milliseconds average, 16-millisecond update
“B” suffix models: 96 milliseconds average, 32-millisecond update
Sensing Performance
(Specied using a 100 x 100 mm
aluminum target at 25˚ C under
xed sensing conditions.)
Analog sensing resolution or discrete output repeatability: ±0.25% of measured distance
“A” suffix models: .5 mm min
“B” suffix models: 1 mm min
Analog linearity: ±0.5% of full-scale span
Min. window size: 10 mm
Hysteresis of discrete output: 2.5 mm
Temperature effect: 0.2% of sensing distance per ° C
Adjustments
Sensing window limits (analog or discrete): TEACH-mode programming of near and far window limits may be set using membrane
push buttons on sensor or remotely using TEACH input. Window limits may be programmed separately, or together.
Analog output slope: the rst limit taught is assigned to the minimum output value (4 mA or 0V).
Indicators
Four status LEDs: In RUN mode:
Green ON Steady: Power ON, RUN mode
Green Flashing: Discrete output is overloaded
Red Flashing: Relative received signal strength
Yellow analog ON Steady: Target is inside window limits
Yellow discrete ON Steady: Output conducting
In Program mode:
Green OFF: PROGRAM mode
Red Flashing: Relative received signal strength
Yellow ON Steady: Ready for rst window limit
Yellow Flashing: Ready for second limit
Yellow OFF: Not teaching this output
Construction
Molded reinforced thermoplastic polyester housing.
Environmental Rating
Leakproof design is rated IEC IP67; NEMA 6P
Connections
2 m or 9 m 5-conductor PVC-covered attached cable, or 5-pin Euro-style quick-disconnect tting.
QD cordsets are ordered separately. See page 325.
Operating Conditions
Temperature: -20° to +70° C Relative humidity: 100%
More
on next
page
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Comentarios a estos manuales