SENSORS
More information online at bannerengineering.com312
LIGHT GAUGING ULTRASONIC MEASURING ARRAYS RADAR
Brackets
QT50U
SMB30A SMB30MM SMB30SC
pg. 639 pg. 640 pg. 641
Cordsets
Micro QD (With Shield)
See page 699
Length
Threaded 5-Pin
Straight Right-Angle
2 m MQVR3S-506 MQVR3S-506RA
5 m MQVR3S-515 MQVR3S-515RA
10 m MQVR3S-530 MQVR3S-530RA
Mini QD (With Shield)
See page 701
Length
Threaded 5-Pin
Straight
2 m MBCC2-506
4 m MBCC2-512
10 m MBCC2-530
U-GAGE
®
QT50U Universal Voltage Specifications
Hysteresis
Window-limit sensor models: 5 mm Fill-level control sensor models: 0 mm
Output Response Time
Selectable 1600, 400 or 100 milliseconds
Minimum Window Size
20 mm
Adjustments
Sensing limits: TEACH-Mode programming of near and far limits may be set using the TEACH push button.
Sensor configuration: Output response time and temperature compensation mode may be set using the Speed push button.
Factory default settings: 400 milliseconds output response time; temperature compensation enabled
Indicators
Green Power ON LED: Indicates power is ON
Red Signal LED: Indicates target is within sensing range, and the condition of the received signal.
Output indicator (bicolor Yellow/Red): Indicates output status or TEACH mode
Response indicator (bicolor Yellow/Red): Indicates output response time selection
Construction
Transducer: Ceramic/Epoxy composite Housing: ABS
Membrane Switch: Polyester
Environmental Rating
Leakproof design is rated IEC IP67; NEMA 6P
Connections
2 m or 9 m shielded 5-conductor (with drain) PVC jacketed attached cable, or 5-pin Micro-style quick-disconnect or 5-pin Mini-style
quick-disconnect. QD cordsets are ordered separately. See page 312.
Operating Conditions
Temperature: -20° to +70° C Relative humidity: 100%
Vibration and
Mechanical Shock
All models meet Mil Std. 202F requirements. Method 201A (vibration: 10 to 60Hz max., double amplitude 0.06", maximum
acceleration 10G). Also meets IEC 947-5-2 requirements: 30G 11 milliseconds duration, half sine wave
Temperature Warmup Drift
Less than 1.0% of sensing distance upon power-up with Temperature Compensation enabled
Application Notes
Objects passing inside the specied minimum sensing distance (200 mm) may produce a false response.
Certifications
Hookup Diagrams
UN09 (p. 755)
(cont’d)
Additional brackets and information available.
See page 620.
Additional cordset information available.
See page 679.
Euro QD (With Shield)
See page 687
Length
Threaded 5-Pin
Straight Right-Angle
2 m MQDEC2-506 MQDEC2-506RA
5 m MQDEC2-515 MQDEC2-515RA
9 m MQDEC2-530 MQDEC2-530RA
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Comentarios a estos manuales