S18U Specifications
Effective Beam
See Charts EBPC-1 and EBPC-2 on page 316.
Supply Voltage and Current 10 to 30V dc (10% max. ripple); 65 mA max. (exclusive of load), 40 mA typical @ 25V input
Ultrasonic Frequency 300 kHz, rep. rate 2.5 milliseconds
Supply Protection Circuitry Protected against reverse polarity and transient voltages
Output Protection Protected against short circuit conditions
Output Ratings
Analog:
Analog Voltage Output: 2.5 kΩ min. load resistance
Minimum supply for a full 10V output is 12V dc (for supply voltages
between 10 and 12, V out max is at least V supply -2)
Analog Current Output: 1 kΩ max @ 24V input
Max load resistance = (Vcc-4)/0.02 Ω
Discrete: 100 mA max.
OFF-state leakage current: less than 5 µA
NPN saturation: less than 200 mV @ 10 mA and less than 600 mV @ 100 mA
PNP saturation: less than 1.2V @ 10 mA and less than 1.6V @ 100 mA
Output Configuration
Analog: 0 to 10V dc or 4 to 20 mA, depending on model
Discrete: Bipolar: One NPN (current sinking) and one PNP (current sourcing) output in each model. Solid-state switch conducts
when target is sensed within sensing window.
Output Response Time
Analog: 30 milliseconds: Black wire at 0-2V dc (or open) Discrete: 5 milliseconds
2.5 milliseconds: Black wire at 5-30V dc
Delay at Power-up
300 milliseconds
Linearity*
(Analog output models)
2.5 milliseconds response: ± 1 mm
30 milliseconds response: ± 0.5 mm
Resolution*
(Analog output models)
2.5 milliseconds response: 1 mm
30 milliseconds response: 0.5 mm
Repeatability
(Discrete models)
0.5 mm
Temperature Effect
0.02% of distance/ ° C
Temperature Warmup Drift
Less than 1.7% of sensing distance upon power-up
Minimum Window Size
5 mm
Switching Hysteresis
(Discrete output models)
0.7 mm
Adjustments
Sensing window limits: TEACH-Mode programming of near and far window limits may be set using the push-button or remotely
using TEACH input.
Indicators
Power/Signal Strength (Red/Green)
Green—Target is within sensing range
Red—Target is outside sensing range
OFF—Sensing power is OFF
TEACH/Output Indicator (Yellow/Red)
Yellow —Target is within taught limits
OFF—Target is outside taught window limits
Red—Sensor is in TEACH mode
Remote TEACH Input
Impedance: 12 kΩ
Construction
Threaded Barrel: Thermoplastic polyester Push-Button Housing: ABS/PC
Push Button: Santoprene Lightpipes: Acrylic
Environmental Rating
Leakproof design is rated IEC IP67; NEMA 6P
Connections
2 m or 9 m shielded 5-conductor (with drain) PVC jacketed attached cable, or 5-pin Euro-style quick-disconnect. QD cordsets are
ordered separately. See page 316.
Operating Conditions
Temperature: -20° to +60° C Relative humidity: 100%