One-Channel EDM Hookup to IM-T-9A Interface Module
The IM-T-9A interface module depicted in the following figure is shown in one-channel EDM hookup. The IM-T-11A module is connected
in a similar manner.
Depending on the application, each Safety Output requires a separate and individually wired IM-T-..A module.
0V dc
S3
S4
Y3
Y1
13
23
33
Y4
Y2
14
24
34
S1
S2
K2 K1
MPCE
2
MPCE
1
IM-T-9A
*
*
1A 1B 2A 2B 3A 3B A2
SO1 SO2 SO3
+24V dc
Feedback (optional)
* Installation of transient (arc) suppressors across the coils of MPCE1 and MPCE2
is recommended (see Warning)
Machine
Control
Input Terminals
Safety Controller
Figure 31. Hookup: One-channel EDM hookup to IM-T-9A interface module
SC22-3/-3E Safety Controller Instruction Manual
48 www.bannerengineering.com - tel: 763-544-3164 P/N 133487 rev. C