Banner SMI30 Series—Intrinsically Safe Manual de usuario Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
Certifications
United States
Intrinsically safe for Class I, Zone 1 AEx ib Group IIC T5 Ta = -40°C to 70°C - 35331; Entity
Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40°C to 70°C
Entity Parameters: V
Max
= 30 V, I
Max
= 350 mA, C
i
=0, L
i
= 0.
a = 6EQ, 6EBQ, 6ECQ, 6EYCQ, AN6RQ, AN6RBQ, AN6RCQ, RN6RQ, RN6RBQ, RN6RCQ, 6EYQ,
N6RYQ, AN6RYCQ, RN6RYQ, RN6RYCQ.
FM12ATEXD094X
LR41887
NRTL/C Exia
INTRINSICALLY SAFE/
SECURITE INTRINSEQUE
Dimensions
Jam Nuts
(2 Provided)
Alignment
Indicator (Receivers)
M30 x 1.5
Thread
157.48 mm
(6.2")
PVC-covered
mini-type QD cable
(25 mm (1”) radius
mininum bend)
Performance Curves
Beam Pattern (10 ms Response Time) Beam Pattern (1 ms Response Time) Excess Gain Curve
150 m
(500')
120 m
(400')
90 m
(300')
60 m
(200')
30 m
(100')
0
0
500 mm
1000 mm
1500 mm
500 mm
1000 mm
1500 mm
0
20"
40"
60"
20"
40"
60"
DISTANCE
SMI30 Series
Opposed Mode
10 ms Response
1
10
100
1 m
(3.3')
10 m
(33')
100 m
(330')
1000 m
(3300')
0.1 m
(0.33')
1000
10000
100000
E
X
C
E
S
S
G
A
I
N
DISTANCE
SMI30 Series
Opposed Mode
1 ms Response models
10 ms Response models
Accessories
APG30S Aperture Kit
These new water-tight apertures for SM30 Series sensors may be used to size and shape the effective beam or to limit excess gain for
avoiding "burn-through" effects. Apertures are sold as a kit, which includes a thread-on stainless steel housing, a flat glass lens, two
quad-ring seals, and 3 round and 3 slotted aperture disks.
SMI30 Series Intrinsically Safe Sensors
6 www.bannerengineering.com - tel: 763-544-3164 P/N 035331 Rev. E
Vista de pagina 5
1 2 3 4 5 6 7 8

Comentarios a estos manuales

Sin comentarios