Advanced sensor with dual displays for use with plastic fiber optics
Easy-to-read 8-segment light bar indicator for teach and signal strength readout, plus
indicators for continuous readout of operating status (user configuration)
Easy-to-set automatic Expert-style configuration options include Static and Dynamic
TEACH, and Window SET, plus manual adjustment for fine tuning
Smart gain-control algorithm to maximize performance in low-contrast applications
Fast 500-microsecond sensing response with improved crosstalk avoidance routine
(for two sensors) in Normal mode
Selectable high-speed (HS) mode option for 200-ms response
Extreme configuration flexibility via push buttons or a remote input wire
Easy selection of Light/Dark Operate (LO/DO), 30 ms pulse stretcher (OFF-delay), and
response speed, via push buttons or a remote input wire
Models available with visible red (680 nm) or visible green (525 nm) sensing beam
Sleek, ultra-slim 10 mm housing, mounts to a standard 35 mm DIN rail
Models with bussable power provide simplified wiring of up to 16 sensors and feature
improved temperature compensation for side-by-side mounting
Models
Model Description Cable* Outputs
Red Beam Green Beam
D10BFP D10BFPG
Standard sensor
2 m (6.5 ft) Cable
Bipolar NPN/PNP
D10BFPQ D10BFPGQ 6-pin Pico-style QD
Models with Bussable Power
D10B5FP - Main unit 2 m (6.5 ft) Cable Bipolar NPN/PNP
D10B2PFP - Sub-unit 2 m (6.5 ft) Cable Single PNP
D10B2NFP - 2 m (6.5 ft) Cable Single NPN
Standard 2 m (6.5 ft) cable models are listed. To order the 9 m (30 ft) cable model, add suffix "W/30" to the cabled model number. For
example, D10xFP W/30. Models with a QD connector require a mating cable. See Accessories.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
Overview
The D10 Expert is an easy-to-use, DIN-rail-mountable fiber optic sensor. It provides high-performance sensing in low-contrast applica-
tions. Configuration options include Setup mode plus Static and Dynamic TEACH, and Window Set options, in addition to manual fine
adjustment, remote programming, and security push button lockout.
D10 Expert Series with Bar Graph Display and Discrete Output
P/N 117830 Rev. F 5/15/2013
0 117830 8
Vista de pagina 0
1 2 3 4 5 6 ... 12 13

Indice de contenidos

Pagina 1 - Overview

Advanced sensor with dual displays for use with plastic fiber optics• Easy-to-read 8-segment light bar indicator for teach and signal strength readout

Pagina 2 - Sensor Configuration

SpecificationsSensing BeamStandard sensors: 660 nm visible red or 525 nm visiblegreen, depending on modelModels with bussable power: 660 nm visible re

Pagina 3

Performance CurvesRed Beam ModelsOpposed Mode Diffuse Mode (Performance based on 90% reflectance whitetest card)1101001000EXCESSGAINDISTANCE11010010 m

Pagina 4

Dimensions61.3 mm (2.42")68.1 mm (2.68")10.5 ± 0.2 mm (typ.) (0.41")Mounting Bracket (included)35.9 mm (1.41")7.6 mm 0.30"9.

Pagina 5 - Single-Point Window Set

AccessoriesQuick Disconnect Cordsets6-Pin Snap-on M8/Pico-Style CordsetsModel Length Style Dimensions PinoutPKG6Z-2 2 m (6.5 ft) Straightø10 mm max.(0

Pagina 6 - Single-Point Light Set

The sensor’s compact housing has a large, easy-to-see bar graph displayplus bright LEDs for easy programming and status monitoring during opera-tion.S

Pagina 7 - Single-Point Dark Set

Static TEACH and Manual Adjust. Using Manual Adjust with Static TEACH moves the switching threshold. The lighted LED on the bargraph will move to exhi

Pagina 8 - Setup Mode

Dynamic TEACH and Adaptive Thresholds• Teach on-the-fly• Establishes a single switching threshold• Threshold position is adjustable using “+” and “-”

Pagina 9 - Manual Adjust

Push Button0.04 seconds < "Click" < 0.8secondsRemote Line0.04 seconds < T < 0.8 secondsResultTEACH UnacceptablePower LED: OFFBar

Pagina 10 - Specifications

Single-Point Light Set• Sets a threshold 6.25% below the taught condition.• Any condition darker than the threshold condition causes the output tochan

Pagina 11 - Performance Curves

Single-Point Dark Set• Sets a threshold 6.25% above the taught condition• Any condition lighter than the threshold condition causes the output tochang

Pagina 12 - Dimensions

Setup ModeUse Setup mode to change sensor output response for:• Light or Dark operate• 30-millisecond pulse stretcher (OFF-delay), if required• 200 μs

Pagina 13 - Accessories

Manual AdjustManual Adjust is used during Run mode and is accomplished using the push buttons only. Its behavior depends on whether a switchingthresho