P/N 63416 rev. A 3
45LM Series Modules
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Selecting ON-Delay Time Range
Switch 4 Switch 5
Delay
(min. to max.)
OFF OFF
OFF – no delay
OFF ON
0.01 to 0.15 sec.
ON OFF
0.1 to 1.5 sec.
ON ON
1 to 15 sec.
Selecting Hold Time (OFF-Delay) Range
Switch 6 Switch 7
Hold
(min. to max.)
OFF OFF
OFF – no hold
OFF ON
0.01 to 0.15 sec.
ON OFF
0.1 to 1.5 sec.
ON ON 1 to 15 sec.
Selecting Output State
Switch 8 Output State
Rate Sensor Logic
ON Output de-energizes above the set rate
OFF Output energizes above the set rate
Flip-Flop Logic
ON Output changes state at trailing edge of signals
OFF Output changes state at leading edge of signals
All Other Logic
ON Normally closed: output de-energizes during Hold time
OFF Normally open: output energizes during Hold time
Output Timing Function: ON-delayed one-shot
Switch 1 Switch 2 Switch 3 Other Settings
OFF ON OFF
Output
Signal
HoldDelay
Output Timing Function: Repeat cycle timer
Switch 1 Switch 2 Switch 3 Other Settings
OFF OFF ON
Output
Signal
HoldDelay HoldDelay
Output Timing Function: Limit timer
Switch 1 Switch 2 Switch 3 Other Settings
ON OFF ON
Output
Signal
Hold
Output Timing Function: Rate sensor
Switch 1 Switch 2 Switch 3 Other Settings
OFF ON ON
Output
< Hold
Signal
> Hold
Output Function: Flip-flop
Switch 1 Switch 2 Switch 3 Other Settings
ON ON ON
Output
Signal