page 2 Banner Engineering Corporation
D11 Features
Installation onto a 35 mm DIN rail
DC Product Specifications
Required Fiber Optic Cable
Adjustments SENSITIVITY control on top of module (15-turn slotted brass screw, clutched at both ends of travel)
Output Configuration Complementary: one normally open (N.O.) and the other normally closed (N.C.); Outputs are NPN(Sinking) or
PNP (Sourcing), depending on model
Output Rating 150 mA maximum (each output); The total load may not exceed 150 mA;
Off-state leakage current: <5 microamps at 30V dc;
On-state saturation voltage: <0.8V at 80 mA dc; <1.5V at 150 mA dc
Output Protection Circuitry Protected against false pulse on power-up (false pulse protection circuit causes a 0.1 second delay on
power-up); short-circuit protected
Output Response Time 500 microseconds "on" and "off"
Indicators Two LEDs: Green and Yellow
GREEN glowing steadily = power to sensor is "on"
GREEN flashing = output is overloaded
YELLOW glowing steadily = normally open output is conducting
YELLOW flashing = marginal excess gain (1-1.5x) in light condition = alarm output "on"
Repeatability Repeatablilty is 160 microseconds; Response time and repeatability are independent of signal strength
Construction Black ABS (Cycolac
®
KJB) flame retardent housing with acrylic cover; Stainless steel M3 x 0.5 hardware for use
with ABS (Cycolac
®
KJB) mounting bracket (supplied)
Environmental Rating IEC IP54; NEMA 2
Connections 2 m (6-1/2 ft) or 9 m (30 ft) attached cable, or 4-pin pico-style quick-disconnect fitting; Cables for QD
models are purchased separately
Operating Temperature -20º to +55ºC (-4º to +131ºF); Maximum relative humidity 90% at 50ºC (non-condensing)
PI or PB Series plastic fibers
Supply Voltage and Current 5V dc (±10%) at 25 mA (exclusive of load current)
Sensing Beam Visible red, 680 nm
Cycolac
®
is a registered trademark of General Electric Company