Q60V Series Adjustable-Field Sensors – Visible Red Emitter
page 6
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Q60V Specifications
LO/DO Toggle
Push Button
ON
OFF
DELAY
–
DELAY
+
Four-Second Press and Hold
Light/Dark Operate Select
Light Operate or Dark Operate mode may be selected using the two push buttons or a
4-second pulse of the remote line to toggle between the selections. See Figure 15.
Push Button Lockout
For security, the push buttons may be locked out using either the remote line or the
push buttons themselves. See Figure 16.
Push Button Lock-out Toggle
Push Button
ON
OFF
DELAY
–
DELAY
+
Concurrent Quad-Click
T TTTTTTTT>800 msT
Figure 15. Light/Dark operate toggle options Figure 16. Lockout toggle
Q60V Adjustable-Field Sensor Dimensions
17.
m
0.67"
77.
m
3.06"
bn
Q60BB6AF200Q
wh
bu
+
–
bk
10-30V dc
Remote Teach
gy
Load
Load
7
.
m
2.95"
2.
m
2.05"
14.
m
0.55"
1
.2 m
0.60"
4.
m
0.19"
7.
m
(2.64"
4.
m
0.16"
4.
m
0.16"
2.
m
2.05"
.
m
2.36"
2
.
m
0.98"
2x
0.17"
M3 hardware is included
ON
OFF
DELAY
DELAY
SIG
RANGE
bn
Q60BB6AF200
wh
bu
+
–
bk
10-30V dc
Remote Teach
gy
Load
Load
–
+
Supply Protection Circuitry Protected against reverse polarity and transient voltages
(Q60VR3 models’ dc hookup is without regard to polarity)
Supply Voltage and Current Q60BB6AFV models: 10 to 30V dc (10% maximum ripple) at less than 50 mA exclusive of load
Q60VR3AFV Universal models: 12 to 250V dc or 24 to 250V ac, 50/60 Hz
Output Configuration Q60BB6AFV models: Bipolar; one NPN (current sinking) and one PNP (current sourcing) open-collector
transistor
Q60VR3AFV cabled model: E/M Relay (SPDT), normally closed and normally open contacts
Q60VR3AFVQ1 (QD) model: E/M Relay (SPST), normally open contact