Remote Line Method (0.04 s < T < 0.8 s)
Step Action Result
1 Position the target at the location where the midpoint of the
window should be.
Min and Max LEDs both flash red (0.5 second), then turn
amber
2
Triple-pulse the remote line
T T
T
T
T
Setting the Maximum Analog Limit
Push Button Method
Step Action Result
1 Position the target at the location where the midpoint of the
window should be.
Its LED flashes red
2 “Click” either push button
3 “Click” the other push button The Red Teach LEDs change to amber and the sensor returns
to RUN mode
Remote Line Method (0.04 s < T < 0.8 s)
Step Action Result
1 Position the target at the location where the midpoint of the
window should be.
Min and Max LEDs both flash red (0.5 second), then turn
amber
2
Triple-pulse the remote line
T T
T
T
T
Push Button Lockout
Enables or disables the keypad to prevent unauthorized personnel from adjusting the programming settings.
Push Button
Remote Line
Procedure Result
Procedure
0.04 sec. < T < 0.8 sec.
Result
Not available via push button Not applicable
Four-pulse the remote line
T T
T T T
T T
Push buttons are either enabled or
disabled, depending on previous
condition.
U-GAGE QT50ULB Series Sensors with Analog Output
6 www.bannerengineering.com - tel: 763-544-3164 P/N 70137 Rev. B