Q60LAF Series Laser Adjustable-Field Sensors
Banner Engineering Corp.
Minneapolis MN, U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Specifications
Supply Voltage and
Current
Q60BB6LAF models:
10 to 30V dc (10% maximum ripple) at less than 35 mA exclusive of load
Q60VR3LAF Universal models:
12 to 250V dc or 24 to 250V ac, 50/60 Hz
Input power 1.5 W maximum
Supply Protection
Protected against reverse polarity and transient voltages
(Q60VR3 models’ dc hookup is without regard to polarity)
Output Configuration
Q60BB6LAF models:
Bipolar; one NPN (current sinking) and one PNP (current sourcing) open-collector
transistor
Q60VR3LAF cabled model:
E/M Relay (SPDT), normally closed and normally open contacts
Q60VR3LAFQ1 (QD) model:
E/M Relay (SPST), normally open contact
Output Rating
Q60BB6LAF models
Q60BB6LAF models
150 mA maximum each output @ 25° C
Off-state leakage current:
< 5µA @ 30V dc
Output sat u ra tion NPN:
< 200 mV @ 10 mA and < 1V @150mA
Output sat u ra tion PNP:
< 1V at 10 mA; < 1.5V at 150 mA
Q60VR3LAF Universal models
Q60VR3LAF Universal models
Min. voltage and current:
5V dc, 10 mA
Mechanical life of relay:
50,000,000 operations
Electrical life of relay at full resistive load:
100,000 operations
Max. switching power (resistive load):
Cabled models:
1250VA, 150 W
QD models:
750VA, 90W
Max. switching voltage (resistive load):
Cabled models:
250V ac, 125V dc
QD models:
250V ac, 125V dc
Max. switching current (resistive load):
Cabled models:
5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc
QD models:
3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc
Output Protection
Circuitry
Q60BB6LAF models:
Protected against continuous overload or short circuit of outputs
All models:
Protected against false pulse on power-up
NOTE: 1 second max. delay at power up (outputs do not conduct during this time).
Output Response Time
Q60BB6LAF models:
2 milliseconds ON and OFF
Q60VR3LAF Universal models:
15 milliseconds ON and OFF
Repeatability
500 microseconds
Sensing Hysteresis
See Figure 4.
Indicators (see Figure 1)
NOTE: Outputs are
active during
on/off timing
selection mode.
ON-Delay
ON Green:
RUN mode, ON-delay active
Flashing Green:
ON-Delay Selection mode
OFF-Delay
ON Green:
RUN mode, OFF-delay active
Flashing Green:
OFF-Delay Selection mode
5-Segment Light Bar*
ON/OFF-Delay Selection:
Indicates relative delay time
RUN Mode:
Output
ON Yellow:
Outputs are conducting
ON Green:
ON/OFF-Delay Selection
Dark Operate
ON Green:
Dark Operate selected
Lockout
ON Green:
Buttons locked out
Light Operate
ON Green:
Light Operate selected
Signal
ON Green:
Sensor receiving signal
Flashing Green:
Marginal signal (1.0 to 2.25 excess gain)
Laser Characteristics
Spot Size:
approximately 4 x 2 mm throughout range (collimated beam)
Angle of Divergence:
5 milliradians
NOTE: Contact factory for custom laser spot size.