Q60LAF Series Laser Adjustable-Field Sensors
www.bannerengineering.com • Tel: 763.544.3164
10 to 30V dc (10% maximum ripple) at less than 35 mA exclusive of load
Q60VR3LAF Universal models:
12 to 250V dc or 24 to 250V ac, 50/60 Hz
Input power 1.5 W maximum
Protected against reverse polarity and transient voltages
(Q60VR3 models’ dc hookup is without regard to polarity)
Bipolar; one NPN (current sinking) and one PNP (current sourcing) open-collector
E/M Relay (SPDT), normally closed and normally open contacts
E/M Relay (SPST), normally open contact
150 mA maximum each output @ 25° C
Off-state leakage current:
Output sat u ra tion NPN:
< 200 mV @ 10 mA and < 1V @150mA
Output sat u ra tion PNP:
< 1V at 10 mA; < 1.5V at 150 mA
Q60VR3LAF Universal models
Q60VR3LAF Universal models
Min. voltage and current:
Mechanical life of relay:
Electrical life of relay at full resistive load:
Max. switching power (resistive load):
Max. switching voltage (resistive load):
Max. switching current (resistive load):
5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc
3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc
Protected against continuous overload or short circuit of outputs
Protected against false pulse on power-up
NOTE: 1 second max. delay at power up (outputs do not conduct during this time).
2 milliseconds ON and OFF
Q60VR3LAF Universal models:
15 milliseconds ON and OFF
Indicators (see Figure 1)
RUN mode, ON-delay active
RUN mode, OFF-delay active
Indicates relative delay time
Marginal signal (1.0 to 2.25 excess gain)
approximately 4 x 2 mm throughout range (collimated beam)
NOTE: Contact factory for custom laser spot size.