Banner PresencePLUS P4 EDGE 1.3 Series Manual de usuario Pagina 216

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 258
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 215
last displayed inspection. Each tool in the list can be expanded to show its results. Each result shown indicates
the tolerance assigned to the parameter and its current value.
If the current value falls within the Test tool’s set tolerance or if the tool executed properly, then a
green checkmark symbol is shown beside that parameter.
If the current value falls outside the Test tool’s set tolerance or if the tool failed to execute properly,
then a red failed symbol is shown beside that parameter.
DescriptionParent LevelLevelName
Name of currently running inspection.NoneFirstCurrent Inspection
Sensor Information:Inspection NameSecondThe Camera
Gain
Exposure time (ms)
Trigger Input Information:Inspection NameSecondThe Trigger
Divide
Delay
Width
Polarity
General Inspection Information:Inspection NameSecondThe Inspection
Manager
Fail hold time (ms): how long a failed image is
displayed on the monitor
P/N 000000Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
216
7/2009Run Screen
Vista de pagina 215
1 2 ... 211 212 213 214 215 216 217 218 219 220 221 ... 257 258

Comentarios a estos manuales

Sin comentarios